Structural Design › Pretensioned U-beam bridge deck
Pretensioned U-beam bridge deck – precast U-beam with composite slab to EN 1992-2, traffic EN 1991-2
The I-beam steps for a precast U-beam: the U outline (two inclined webs, haunches, bottom flange, top lips), materials, a bridge load table with γ, ψ and a tick, load combinations, SLS stresses, ULS bending, shear over both webs and interface shear, deflection and bearing schedule, end block with a solid end and the debonding design, design sketches and an A4 report.
Calculation method
EN 1992-1-1 / EN 1992-2 as the I-beam: losses 5.10.4–5.10.6, transmission 8.10.2, staged stresses on the precast and composite sections, ULS strain compatibility with prestrain (6.1), shear 6.2.3 / 6.4 with both webs, interface 6.2.5 over the two top lips, SLS 7.2 and Table 7.101N; end block fib Model Code 2010 7.13 with a solid end. The U-section is built from its outline (two inclined webs, haunches, bottom flange) as an equivalent stack of widths, exact for the area, centroid, second moment and the stress block. Loads EN 1991-2, EN 1991-1-4, EN 1991-1-5; combinations EN 1990 A2.
About
Free online calculator by My Formulas, a reference for design and education. Enter the inputs, get the results at once, and open the step-by-step calculation (free member account) to check every value. Verify results independently before use.
Related tools
- Beam calculator – cantilever, simply supported, fixed and continuous beams
- Two-way slab moments – edges pinned, edges fixed, corner supported
- RC section design to EN 1992-1-1 – rectangular, circular and bored piles
- Steel section properties and member capacity to EN 1993-1-1
- Steel member selection – lightest I-section, RHS, SHS or CHS
- Double strut design – laced I-section chords to EN 1993-1-1
- Spun pile design – pretensioned hollow concrete pile to EN 1992-1-1
- Concrete-filled circular hollow section (CFCH) – steel pipe pile N–M interaction and buckling to EN 1994-1-1
- Concrete-filled rectangular hollow section (CFRH) – composite column N–M interaction and buckling to EN 1994-1-1
- Concrete-encased universal column (CEUC) – encased I / H section N–M interaction and buckling to EN 1994-1-1
- Portal frame calculator – multi-bay, two-storey portal, gable and mono-pitch frames
- Pretensioned I-beam bridge deck – precast beam with composite slab to EN 1992-2, traffic EN 1991-2
- Pedestrian truss bridge – two trusses with a deck, EN 1991-2 Section 5
- Road truss bridge – two trusses with a deck, EN 1991-2 LM1 and LM2
- Truss bridge calculator – paired trusses with deck and moving vehicle
- Truss calculator – triangular, parallel chord and bowstring trusses